• Menu
  • Skip to primary navigation
  • Skip to main content

Kuefler Lightning

Kuefler Lightning

Header Right

View Quote List
MENUMENU
  • Home
  • Request a Quote
  • Product Categories
        • Lightning Conductor
        • Aluminum Air Terminals, Tripod Supports, & Accessories
        • Copper Air Terminals, Tripod Supports, & Accessories
        • Lightning Protection Finials
        • Air Terminal Bases
        • Conductor Splicers & Cable Splicers
        • Bonding Plates, Bonding Lugs, Bonding Pipe Clamps, Computer Room Grounding, & Bonding Straps
        • Through Roof, Wall Connections & Accessories
        • Conductor Fasteners & Accessories
        • Grounding Rods, Plates, Chemical Ground Rods, and Clamps
        • Aircraft Static Grounding
        • Grounding Bus Bars & Accessories
        • Grounding Access Wells
        • Exothermic Weld & Accessories
        • Oil Field Lightning Protection
        • Compression Lugs & Accessories
        • Surge Protection
        • Weathervanes, Glass Ornaments, & Accessories
        • Lightning Strike Counters
        • Heavy-Duty Smokestacks/Exhaust Stacks
        • Catenary  
        • Tree Lightning Protection
        • Lightning Protection Tools
  • Pictures/Videos
  • Library
    • Brochures
    • Lightning Safety
    • Risk Assessment
    • Lightning Protection Codes and Standards
    • Service Areas
    • Forest Fire Lookout Towers
  • About
  • Contact
  • Quote List
MENUMENU
  • Home
  • Request a Quote
  • Product Categories
        • Lightning Conductor
        • Aluminum Air Terminals, Tripod Supports, & Accessories
        • Copper Air Terminals, Tripod Supports, & Accessories
        • Lightning Protection Finials
        • Air Terminal Bases
        • Conductor Splicers & Cable Splicers
        • Bonding Plates, Bonding Lugs, Bonding Pipe Clamps, Computer Room Grounding, & Bonding Straps
        • Through Roof, Wall Connections & Accessories
        • Conductor Fasteners & Accessories
        • Grounding Rods, Plates, Chemical Ground Rods, and Clamps
        • Aircraft Static Grounding
        • Grounding Bus Bars & Accessories
        • Grounding Access Wells
        • Exothermic Weld & Accessories
        • Oil Field Lightning Protection
        • Compression Lugs & Accessories
        • Surge Protection
        • Weathervanes, Glass Ornaments, & Accessories
        • Lightning Strike Counters
        • Heavy-Duty Smokestacks/Exhaust Stacks
        • Catenary  
        • Tree Lightning Protection
        • Lightning Protection Tools
  • Pictures/Videos
  • Library
    • Brochures
    • Lightning Safety
    • Risk Assessment
    • Lightning Protection Codes and Standards
    • Service Areas
    • Forest Fire Lookout Towers
  • About
  • Contact
  • Quote List
📞 800 370 5886 | 406 745 3800 | Email: mkuefler@kuefler-lightning.com | Employment Opportunities
| | |

Roof Lightning Protection

Lightning Protection for Roofers and Roofing Consultants

Roofing warranty and lightning protection system verification:
Lightning protection system work cannot begin while the information in this note is not verified. It must be verified by the roofing contractor or roofing manufacturer. Roof-mounted lightning protection equipment being adhered or mechanically fastened directly to the membrane, shingles, tiles, metal roofing or etc. Any variance or special provisions dictated by roofing manufacturer to maintain roofing warranty to be furnished/installed by roofing contractor. (i.e. Additional membrane strips, pavers, flashings, heat welded straps, standing seam clips, adhesive and etc.)

While working on re-roofing projects that have a lightning protection or lightning rod system installed and the lightning protection system must be replaced when the new roof is complete:
The system must be installed following the lightning protection standards. (LPI-175, NFPA780, and UL 96A)
KLP, Inc. recommends contacting us before you start on the re-roofing project to see how we may assist you with technical support, parts, materials, installation standards, 8” Radius Gauge and design drawings (if needed).

“CERTIFICATION” Structures with existing lightning protection systems that are currently certified by UL or LPI and require recertification:
Must be reinstalled to comply with re-certification requirements. This can be accomplished by working with KLP, Inc. for guidance in addition totechnical support to assure your reroofing project is a success. Below are some of the more common lightning protection products used by roofing contractors.

KLP, Inc. has worked with numerous roofing contractors and roofing consultants on reinstalling lightning rods and materials. (Such as lightning conductor, conductor fasteners, air terminals, air terminal bases, conductor splicers, and bonds)

KLP, Inc. has seen in the past roofing contractors throwing back together a lightning protection system and not understanding proper installation techniques. If the system is installed incorrectly and fails during a lightning strike this could lead to costly repairs and liability issues for the roofing contractor or roofing consultant.

Please give us a call to discuss your lightning protection project! 800 370 5886

If you don't see what you're looking for, give us a call at 800-370-5886.
We have many parts available that are not listed on our site.

We Accept Visa, Mastercard, Discover and American Express Cards & Checks:
Credit Card Logos for Visa, Mastercard, Discover and American Express

Email: mkuefler@kuefler-lightning.com
KLP, Inc. PO Box 209, St. Ignatius, MT (Montana), 59865.
Phone: 406-745-3800, Fax: 406-745-3820, Toll Free: 800-370-5886.
We also have offices in Florida and Minnesota.
See our Service Areas page for more information.

Copyright © 2026 KLP, Inc.
Home · Terms of Service · Privacy Policy · Log in